The Dingtian DT-008's Windows-only config tool speaks a small binary UDP protocol (reader :24680 unicast get/set, :24582 broadcast search/set-network), reversed in wiki/raw/dingtian_qr_linux (PROTOCOL.md + dingtian_qr.py, copied to scripts/). Reading park-2's readers with it from the booth found both in WG26 output mode — the "beeps but captures nothing" enrolment failure: they never pushed HTTP at all. The app now speaks the protocol itself (packages/devices dingtian-qr-config.ts, Node dgram, host-network container) and the dingtian-qr-reader driver uses it: - discover(): first driver to implement the wizard's Scan capability; rows show serial, IP, output mode, current server target, card format, firmware. - preconditions: output type must be HTTP (fixable — save switches it); typed serial must equal the reported one and the reader must answer on UDP (both block the save). - configureInputPush(): set-network the reader's server to this booth's IP + listen port, confirmed by polling (the reader applies it without an ack and is silent for seconds). - usesPushAuth=false: the scan GET carries no credentials, so no push secret is stored. - a reader saved without an IP warns instead of failing (legacy vendor-tool setup). Verified on the bench unit: WG26→HTTP, target 8080→8081→8080, struct byte-identical after. 15 protocol tests against a fake reader + 17 adapter tests. Wiki: device-discovery, first-run-setup, dingtian-dt008-reader, site-device-installation §2 (SSH procedure; the "needs a Windows laptop" claim withdrawn), new source page dingtian-qr-linux-tool.
4.5 KiB
type, tags, sources, updated
| type | tags | sources | updated | |||||
|---|---|---|---|---|---|---|---|---|
| concept |
|
|
2026-10-08 |
First-Run Setup (device selection)
The admin install flow that makes the system device-agnostic in practice: on first run, an admin adds controllers (each declaring its relays — entry/exit/both — the entry-button terminal, and the one-car-one-ticket guard: a presence-loop input or a cooldown, see entry-double-press) and then readers/cameras/printers bound to a controller relay, choosing from the device-registry catalog and entering each device's connection config. There is no lane — the pool-of-spaces model; see entry-exit-points.
Implementation-derived (from
apps/server+apps/web), not the source doc.
Flow
- Read the catalog —
GET /api/setup/catalogreturns supported drivers per category (no secrets, just schema) plus adiscoverablelist. The webSetupWizardrenders a picker + the driver's config fields, and a Scan button for discoverable drivers (device-discovery). - Test (optional, no save) —
POST /api/setup/test(admin-only). Validates the config, probes reachability (healthCheck), and reports preconditions (e.g.input_link_relay) — without saving or changing the device. The wizard's Test connection button shows a health badge + any precondition warnings. - Save & configure —
POST /api/setup/assign(admin-only). Validates, then configures the device: fixes preconditions (e.g. disablesinput_link_relay) and sets up the Digest- authenticated input push (device-input-flow) — the admin never touches the device's own web UI. Fails the save (no DB row) if the device can't be configured, so there are no orphan/half-configured rows. On success persists todevices. DT-008 readers (2026-10-08) go through the same pipeline when their IP is given: the precondition check reads the reader over the vendor UDP protocol (dingtian-qr-linux-tool) and reports output type ≠ HTTP (fixable — the save switches it) and typed serial ≠ reported serial (not fixable — the admin must enter the real one);configureInputPushthen set-networks the reader's push target to this booth's IP + listen port and confirms it by re-reading (the reader is silent for a few seconds after the write, so it polls). The reader's scan GET carries no credentials, so no push user/password is persisted for it (usesPushAuth = false). With no IP nothing is configured and the save succeeds with a warning — the reader must then be set up with the vendor tool /scripts/dingtian_qr.py(site-device-installation §2). - Remove —
DELETE /api/setup/assign/:id(admin-only) drops one instance's row. Only our row is removed; the device itself is not un-hardened/un-configured (a stale push from an unknown device id is already rejected, and re-assigning reconfigures it). - Complete —
POST /api/setup/completemarks the single-rowsetup_state.
Config granularity — multi-instance per category
The data model is multi-instance: devices holds one row per instance, keyed by a
generated id. So the site can have more than one of every category — multiple controllers,
readers, cameras, and printers (e.g. an entry dispenser + a booth printer; see
printer-roles-failover). assign always inserts a new row (never an upsert), and state
returns the full list.
The SetupWizard reflects this: each category shows the list of assigned instances (with
Remove) plus an Add another form — not a single fixed slot. select-type config fields
(e.g. a printer's role) render as dropdowns.
There is no lane. Direction lives on each access relay; readers/cameras bind to a
controller relay (config.controllerId + relay) — the barrier they serve — and inherit its
direction. The wizard adds controllers first, then binds the other devices to a relay. See
entry-exit-points, entry-exit-readers.
Security notes
- The assign/state/delete/complete endpoints require the admin role (local-jwt-auth).
- Device credentials are stored in
devices.config— protect at rest (disk-os-hardening); device hosts belong on the isolated VLAN (network-isolation). - Secrets are stripped on the way out:
assignandstateboth redactpushPassword,webPassword, andrelayPasswordfrom the returned config (the UI lists devices; it never needs the stored secrets).