494c11ddbf
Build & push images / images (push) Successful in 4m55s
The user's rule from 2026-11-22: the system is not ready to control the barrier yet. Container zg2 is stopped, relays read off beforehand; notes how to bring it back. Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01RZgP5oZdzvo92Eouc9eRv5
379 lines
22 KiB
Markdown
379 lines
22 KiB
Markdown
---
|
||
type: concept
|
||
tags: [parking, vision, anpr, passage, relay, poc, park-lab]
|
||
sources: []
|
||
updated: 2026-11-22
|
||
---
|
||
|
||
# Zone ANPR PoC — field trials on park-lab
|
||
|
||
A vendor-neutral, NVR-style prototype of [[passage-confirmation]], run on park-lab against the real
|
||
lane, relays and barrier. Code: `poc/zone-anpr/` (`zone_anpr.py`, with its checks in `test_flow.py`
|
||
and the recorded drives in `recordings/`). It runs on park-lab as container `zg2`, with its page
|
||
on port 8094. Camera and relay credentials come from the environment only.
|
||
|
||
**Status (user, 2026-11-22):** the PoC has served its purpose. The flow and the relay rules work on
|
||
a live barrier; the plate and the detector do not hold on a wet night. Further hardening is
|
||
deferred to a later session, and the work list is on [[vision-hardening]].
|
||
|
||
**Shut down (user, 2026-11-22, evening):** container `zg2` is stopped, with all four relays read
|
||
off beforehand. The user's rule for now: *the barrier is operated only with the staff's remote
|
||
control; our system is not ready to control the barrier yet.*
|
||
|
||
- **Seeing the car:**
|
||
- the **low-res MJPEG stream** (1280×720), about 5 frames a second through YOLOX-Tiny on the Intel
|
||
iGPU;
|
||
- the same frames give the car's position against the drawn line: side A, on the line, or side B.
|
||
- **Reading the plate** ([[zone-anpr-plate-trials]]):
|
||
- **hi-res stills**, and the stream frames as a second source, CPU OCR, in the background;
|
||
- consensus of 3 votes and 75% agreement, every character ≥ 0.9;
|
||
- **no country or format rule** (user: the Albanian rule was "unacceptable").
|
||
- **Records:**
|
||
- `out/visits.jsonl` (the verdict per visit);
|
||
- `out/relays.jsonl` (every pulse, live or would-be);
|
||
- `out/reads.jsonl` (the plate per visit) and `out/reads-all.jsonl` (every read);
|
||
- `out/clips/` (every processed frame of a visit with its box, and the stills with their
|
||
reads).
|
||
|
||
## The flow (user, 2026-11-21)
|
||
|
||
> **Replaced (user, 2026-11-22).** The new flow is on [[passage-confirmation]], "Decided with the
|
||
> user (2026-11-22)", and is built: see [[#The 2026-11-22 build — new flow, relay rules, R2 live]].
|
||
> What follows is the 2026-11-21 flow, kept for the record of that night's trials.
|
||
|
||
1. **A car comes into a zone.** It counts when the detector is ≥ 0.4 sure and ≥ 20% of the car's
|
||
box lies in the zone. If the **other camera already owns the lane**, the car is ignored (see
|
||
[[#Shared lane]]). Otherwise a **visit** starts, and **R1 opens**.
|
||
2. **While the car is in the zone**, its side is noted on every frame. The plate is read on the
|
||
side, and nothing waits for it.
|
||
3. **The visit ends when the zone is free**:
|
||
- the car has been out of the zone for 1 s, or
|
||
- the car has not been seen at all for 3 s.
|
||
4. **The decision is made at once:**
|
||
|
||
| What the car did | Verdict | R2 |
|
||
|---|---|---|
|
||
| From A, ended fully on B | passed | nothing |
|
||
| Came toward the line or onto it, went back to A | **abandoned** | **close** |
|
||
| Stayed on A and never came closer | moving away | nothing |
|
||
| From B to A | other direction | nothing |
|
||
| Lost while on the line, or similar | unclear | nothing — the boom stays up |
|
||
| Started on B and stayed there | stayed beyond | nothing |
|
||
|
||
R2 fires only if R1 opened in the same visit.
|
||
|
||
**The user's rule for the close:** *"As soon as the zone is free and the crossing is abandoned we
|
||
fire R2."* How long a car stands in the lane does not matter. There is no dwell timer and no
|
||
window. This answers the dwell/window open question on [[passage-confirmation]].
|
||
|
||
**Trial settings, not the design:**
|
||
- R1 opens for **any** car. In the design it opens on a known plate or a ticket.
|
||
- R2 is a **dry run**: it is logged as "WOULD PULSE R2" and closes nothing, until the
|
||
preconditions on [[passage-confirmation]] are met.
|
||
- Relays are **disarmed by default** and arm for 30 min. A restart disarms them. The lane has
|
||
no wifi, so arming was done remotely (`POST /arm` on park-lab).
|
||
|
||
## The 2026-11-22 build — new flow, relay rules, R2 live
|
||
|
||
`zone_anpr.py` now implements the flow and the relay rules decided on [[passage-confirmation]]
|
||
("Decided with the user (2026-11-22)").
|
||
|
||
**Deployed to park-lab on 2026-11-22** (user: "Deploy"), container `zg2` restarted at 09:56 UTC:
|
||
- `"close_live": true` is set in its config, so R2 is live once the relays are armed;
|
||
- it came up **disarmed**, with both streams live and the board answering (all relays off);
|
||
- the 44 checks also pass inside the container;
|
||
- the previous file and config are kept beside it as `zone_anpr.py.bak-20261122-preflow` and
|
||
`config.json.bak-20261122-preclose`.
|
||
|
||
**`close_on_lost` is on, on park-lab (user, 2026-11-22).** After the user's point that the
|
||
barrier's own sensors cover the space under the boom, the config got `"close_on_lost": true` and
|
||
`zg2` was restarted at 10:00 UTC. A car the detector loses inside the zone now gives `abandoned`
|
||
and R2, like any other uncrossed open. The code's default stays off.
|
||
|
||
**The flow, as built:**
|
||
|
||
- A visit is one **busy period of the zone**. It starts as before, on a sure car in the zone, with
|
||
one R1.
|
||
- **Busy** means any vehicle in that camera's zone, at the low keep threshold (0.15), not only
|
||
the car being followed.
|
||
- A **crossing** is the followed car changing from fully on one side to fully on the other. The
|
||
last one replaces the one before. A car last seen on the line with its box at the picture's
|
||
edge counts as having left on that side, as before.
|
||
- Nothing is decided while the zone is busy. When it is free: last crossing A → B is `passed`;
|
||
anything else is `abandoned`, and R2 is asked for if R1 opened in that period.
|
||
- The line's `direction` is ignored: A → B is always in. The page has only "Swap A/B" left.
|
||
|
||
**Three defaults the user has not ruled on** (the "not settled" list on [[passage-confirmation]]):
|
||
|
||
- **A car that vanishes inside the zone gives `unclear` and no close.** The zone counts as free
|
||
only when the followed car was seen outside it. A car that drops out with its box at the
|
||
picture's edge does not count either. `"close_on_lost": true` in the config turns this off and
|
||
closes on a lost car too.
|
||
- **Busy looks at the camera's own zone only**, not at the other camera's.
|
||
- **A drive-out (B → A) is `abandoned` and fires R2**, as the flow says.
|
||
|
||
**The relay rules, as built:**
|
||
|
||
- One worker sends everything to the board, in order.
|
||
- Before a pulse it reads the status. Other relay off: fire. Other relay on: off command, read
|
||
again, and so on until it reads off. This is the same for open and close.
|
||
- A failed read or pulse is followed by an **online probe**: a TCP connect to the board's web
|
||
port (`relays.http_port`, default 80). Online: keep looping. Not online: the command is dropped
|
||
and the page shows **RELAY CONTROLLER OFFLINE**.
|
||
- **Immediately before every datagram** the command is checked again: still armed, not replaced
|
||
by a newer command, and still valid. A close is valid only while no visit is running, the zone
|
||
is not busy, and the last processed frame is under 1 s old. So an open never waits behind a
|
||
close that is still trying.
|
||
- While disarmed, or for a close with `close_live` off, **nothing** is sent: no pulse, no off
|
||
command, no read.
|
||
- Timing: 0.4 s for a reply, 0.1 s between tries (`relays.timeout_s`, `relays.retry_s`).
|
||
- The page has a "Read board" button (a status read, which moves nothing).
|
||
|
||
**Checked against the real board** (one status read from inside `zg2`, 2026-11-22): the reply was
|
||
`ffaa5a00000f`, session and command echoed, relays all off, in 42 ms. The web port 80 is open.
|
||
|
||
**Tests.** `poc/zone-anpr/test_flow.py` had 44 checks at this build, all passing, in three parts:
|
||
the flow on scripted boxes; the relay rules against a mock board, datagram by datagram; and a real
|
||
camera object wired to the real relay code and the mock board, armed with the close live. It
|
||
needs no camera, model or relay.
|
||
|
||
**Replay of the recorded night drive.** The boxes park-lab recorded for each visit
|
||
(`out/clips/*/frames.jsonl`) were fed through the new code, with the line that was in force
|
||
during the drive. Of the 23 entry visits, 21 have an old record to compare with, and the side
|
||
paths came out identical for all 21.
|
||
|
||
| Old verdict | Visits | New |
|
||
|---|---|---|
|
||
| passed | 7 | passed, no R2 |
|
||
| abandoned, the car followed out of the zone (17:02, 17:03, 17:36, 17:55, 17:56) | 5 | abandoned, R2 |
|
||
| abandoned, the recording ends with the car inside the zone (16:35, 16:37, 17:04, 17:05) | 4 | unclear, no R2 |
|
||
| other direction (16:34, 17:00, 17:54) | 3 | abandoned (B → A), R2 |
|
||
| stayed beyond | 1 | passed |
|
||
| moving away | 1 | unclear |
|
||
| cut off by a restart (17:33, 17:58) | 2 | abandoned and unclear |
|
||
|
||
- Of the nine entry drives the user confirmed live, the seven from 17:28 on come out as before,
|
||
except 17:54: the drive-out is now `abandoned` with R2, which is what the new flow says.
|
||
- The two confirmed abandonments at 16:35 and 16:37 become `unclear`, and so do 17:04 and 17:05.
|
||
In all four the old tracker lost the car while it was still in the zone:
|
||
- 16:35 and 16:37 have gaps of 6 s and 3 s between frames (the tracking loop was blocked);
|
||
- at 17:04 and 17:05 the reversing car was dropped with a quarter of its box still in the zone.
|
||
|
||
All four were recorded before the 17:20 restart. The three abandonments recorded after it
|
||
(17:36, 17:55, 17:56) were followed until the car was fully out of the zone, and they close.
|
||
**This is what the "no close on a lost car" default costs:** a turn-back the detector drops
|
||
inside the zone leaves the boom up.
|
||
- 16:35 is partly an artefact: the replay treats a gap between recorded frames as frames with no
|
||
car, where the real loop was standing still.
|
||
- A second replay ran the real detector on the saved frames (on the CPU, where park-lab uses the
|
||
iGPU). No visit was held open by other vehicles in the zone. Two short visits came out
|
||
differently because the boxes differ slightly between the two devices.
|
||
- The clips hold only frames in which the old tracker matched the car, so the replay cannot show
|
||
how often something else keeps the zone busy after a visit.
|
||
|
||
**Limits of this build:**
|
||
|
||
- The tracker is unchanged: one followed car, matched by overlap. A track that breaks or jumps to
|
||
another car now ends in `unclear`, or in a late decision, never in a close with a vehicle in
|
||
the zone.
|
||
- A second car that enters the zone before the first has left gets no open of its own.
|
||
- The exit camera has `relay_open` and no `relay_close`. While it owns the lane the entry camera
|
||
yields, so no close can come for that car.
|
||
- The lane lock, the plate stills and the disk items of [[zone-anpr-poc-review]] are untouched.
|
||
|
||
**R2 live (user, 2026-11-22: "this time we will try live firing of R2").** `close_live` is set on
|
||
park-lab; arming on the page is all that is left.
|
||
The three preconditions under "Still open" are **not met**: the interlock has not been checked
|
||
with a meter, the `DET`/`PHO` reversal has not been proven on the unit, and [[barrier-not-a-door]]
|
||
has not been revised. The user chose to run the trial anyway.
|
||
|
||
**Under the boom is the barrier's job (user, 2026-11-22):** *"The barrier always has radars or
|
||
infrared sensors that monitor the under the boom... If there is something the boom will not get
|
||
down whatever the relay commands."* So the PoC's "zone free" does not have to cover the space
|
||
under the boom, and nothing needs checking on the page before arming. This is the same split as
|
||
[[barrier-not-a-door]]: safety is in the barrier's firmware, the host only expresses intent. The
|
||
bench test of it on the park-lab unit ([[passage-confirmation]], test plan steps 2–3) has not
|
||
been run.
|
||
|
||
### Since the first build
|
||
|
||
The same day brought two more builds, both described on [[zone-anpr-plate-trials]]:
|
||
|
||
- **The plate build (deployed 11:15 UTC):** the stream frames as a second source beside the
|
||
stills, the stills kept with their reads, a new HTTP client for every still.
|
||
- **Two fixes after the night trial (deployed 16:54 UTC):**
|
||
- a side, and "outside the zone", count only after two looks in a row, and the leaving edge is
|
||
judged on the last box that agreed with the car's side. A stray last box had turned a
|
||
crossing into `abandoned`, and R2 had fired behind the car;
|
||
- a read does not vote when the picture is burnt out right beside the plate.
|
||
- **Checks now:** `test_flow.py` has 65. `replay_recordings.py` replays the 48 recorded entry
|
||
visits of both days from their recorded boxes: of the 21 where the driver said what he did, 20
|
||
are judged right with `close_on_lost` on (two of them would be `unclear` without it). The one
|
||
miss is the turn-back of 10:18 below, recorded while the zone still ended short of the picture's
|
||
edge.
|
||
- **park-lab has the file that is in the repository** (checked 2026-11-22), with `close_live` and
|
||
`close_on_lost` on in its config. The container is stopped; started again, it comes up disarmed.
|
||
|
||
## Live R2 trial (2026-11-22, AA927AU, UTC, daylight)
|
||
|
||
Relays armed at 10:00:50 with the close live and `close_on_lost` on. The table is what the PoC
|
||
logged. **The user confirmed that the boom came down at every abandonment** of the first run.
|
||
|
||
| Time | Camera | What the user did | Verdict | Relays |
|
||
|---|---|---|---|---|
|
||
| 10:02:45 | entry | drove through | passed (A → B at 10:02:54) | R1 |
|
||
| 10:03:15 | exit | the same car, driving on | abandoned (lost in the zone) | **R1 again**, no close possible |
|
||
| 10:03:42 | entry | abandoned the crossing | abandoned, zone free at 10:03:49 | R1, then **R2 sent** |
|
||
| 10:03:59 | entry | stood in the zone for 2 min 50 s, then abandoned | abandoned, zone free at 10:06:49 | R1, then **R2 sent** |
|
||
|
||
| 10:09:57 | entry | drove in | passed (A → B at 10:10:05) | R1 |
|
||
| 10:10:24 | exit | drove out | abandoned (lost in the zone) | R1, no close possible |
|
||
| 10:10:49 | entry | abandoned the crossing | abandoned, zone free at 10:10:57 | R1, then **R2 sent** |
|
||
|
||
- **All three closes went out live** and the board acknowledged them. The first two are the first
|
||
live R2 pulses.
|
||
- **The drive-out at 10:10:24 was handled by the exit camera alone.** It owned the lane, so the
|
||
entry camera yielded and saw no B → A crossing. The exit camera opened R1 and judged the pass
|
||
`abandoned`, which is the wrong word for it; it has no close relay, so nothing was sent.
|
||
- **Nothing was decided while the car stood in the zone** (10:03:59 to 10:06:49).
|
||
- **Every pulse was preceded by a status read**, and the other relay never read on.
|
||
- **The exit camera opened the barrier a second time for a car that had passed** (10:03:15,
|
||
twenty seconds after the crossing). The entry visit had ended, so the lane lock no longer held
|
||
it: finding 7 on [[zone-anpr-poc-review]]. The exit camera has no close relay, so that open
|
||
stayed until the next close.
|
||
|
||
### A turn-back judged as passed (10:18–10:22)
|
||
|
||
The user drove up, stood in front of the boom for three minutes and then reversed. The PoC
|
||
recorded `passed` at 10:21:08, and the boom stayed up.
|
||
|
||
- **The entry camera does not see the boom.** A car waiting in front of it stands mostly to the
|
||
right of the picture: from 10:18:14 only its rear was in view, and by 10:21:05 a strip between
|
||
x 0.91 and the edge.
|
||
- **That strip lay right of the line** (x 0.85–0.91), so the car read "on side B": a crossing
|
||
A → B.
|
||
- **The zone ends at x 0.94–0.95, short of the picture's edge.** Only a fifth of the strip was
|
||
inside it, so the zone read free a second later, and the visit was decided: passed.
|
||
- **The reversal was not seen.** With the entry visit over, the exit camera took the lane at
|
||
10:21:19 and fired R1. The entry camera ignored the car as it backed through its zone (10:22:00,
|
||
"lane busy with exit"). The exit camera judged `abandoned`, and it has no close relay.
|
||
|
||
Replayed on the recorded boxes with the **zone drawn to the picture's right edge**: the strip is
|
||
57% inside the zone, the visit stays busy, and then a car that drives on gives `passed`, and one
|
||
that reverses gives B → A, `abandoned` and R2. So the fix is the zone drawing, plus taking the
|
||
exit camera out of the lane (below).
|
||
|
||
### park-lab is the worst case (user, 2026-11-22)
|
||
|
||
The user's reading of the trial: park-lab is the hardest site there is. One lane serves entry and
|
||
exit, and the raised boom crosses the exit camera's picture.
|
||
|
||
- **Only park-lab has these problems:** the lane lock between two cameras, a drive-out that reads
|
||
as B → A on the entry line, and the exit camera opening for a car the entry camera should judge.
|
||
park-2 and park-buzi have two lanes and two barriers ([[passage-confirmation]]), so each camera
|
||
sees one direction.
|
||
- **Every site has these:** the camera has to see the car up to the boom, the zone has to reach
|
||
the picture's edge on that side, and a car the detector loses must be handled.
|
||
- **What the trial showed regardless of the site:** the flow and the read-then-fire relay rules
|
||
work on a live barrier, and the boom came down at every abandonment the entry camera judged.
|
||
|
||
## Night drive results (2026-11-21, AA927AU, UTC)
|
||
|
||
The user drove and confirmed each move live.
|
||
|
||
| Time | Camera | What the user did | Verdict | Right? |
|
||
|---|---|---|---|---|
|
||
| 16:35 | entry | stopped, reversed out | abandoned | ✅ |
|
||
| 16:37 | entry | stopped short of the line, reversed out | abandoned | ✅ |
|
||
| 17:28 | entry | drove through | passed | ✅ |
|
||
| 17:36 | entry | to the line, reversed | abandoned, R2 would close | ✅ |
|
||
| 17:52 | entry | drove through | passed | ✅ |
|
||
| 17:54 | entry | drove out toward the street | other direction | ✅ |
|
||
| 17:55 | entry | up to the line, reversed | abandoned, R2 would close | ✅ |
|
||
| 17:56 | entry | **nose over the line**, reversed | abandoned, R2 would close | ✅ |
|
||
| 17:59 | entry | stood ~50 s, then drove through | passed | ✅ |
|
||
| 17:32 | exit | drove out | moving away | ❌ |
|
||
| 17:53 | exit | reversed | abandoned | ✅ |
|
||
| 18:00 | exit | drove out | moving away | ❌ |
|
||
|
||
**Entry: every move judged right**, including the hard one (nose over the line, then back).
|
||
**Exit: not usable** (below).
|
||
|
||
## The back-and-forth — what failed and what replaced it
|
||
|
||
1. **R2 on "the car left the zone" (first try).** On the recordings it missed both turn-backs,
|
||
because a reversing car still overlaps the zone. It also produced a false close on a car waiting
|
||
outside the zone.
|
||
2. **R2 on retreat distance: 0.12 of the frame, held 2 s (second try).** It never fired on the
|
||
real drive. Once fully back on side A, a reversing car is in view for well under a second. The
|
||
user rejected waiting at all. That led to the flow above.
|
||
3. **The visit ended only when the car left the camera's view.** A car reversing down the street
|
||
was followed for minutes, so the verdict and R2 never came. Fix: the zone counts as **free**
|
||
after 1 s out of the zone.
|
||
4. **Plate stills blocked the tracking loop.** A hung still (3 s timeout, 11 times in 3 minutes
|
||
at night) froze the track, so a reversing car vanished between two frames. Fix: the plate read
|
||
runs in the background, at most one at a time per camera.
|
||
5. **The camera was being hammered.** Failed stills were retried on every frame. The camera
|
||
answered `503`, then `digest auth failed` about 5 times a second. That risks an account
|
||
lockout, which would cut the video stream too. Fix: back off 2, 4, 8 … up to 30 s after a
|
||
failure. **Root cause not found:** a still normally takes about 200 ms, and the night hangs are
|
||
unexplained.
|
||
**Likely cause, from [[zone-anpr-poc-review]] (finding 13):** `digest auth failed` is also what
|
||
the PoC's own HTTP client says once it has given up, which it does for good after six failed
|
||
stills in a row. It then sends no credentials, and the back-off does not cure it. Not yet
|
||
checked against the container log.
|
||
6. **Both cameras opened for the same car.** At 16:36 a car got an open from the entry camera
|
||
and another one 6 s later from the exit camera. Fix: a **lane lock**, see
|
||
[[#Shared lane]].
|
||
7. **A crop around the zone cut a close car in half.** The exit camera then saw no car at all.
|
||
Fix: detection runs on the whole frame. It costs the same, because the detector resizes anyway.
|
||
8. **Detection flickered in headlight glare.** A standing car scored 0.4–0.5 and dropped out for
|
||
3 s at a time. Each drop ended the visit, and the next sighting opened the barrier again. Fix:
|
||
a visit **starts** at ≥ 0.4 and **keeps** the car down to 0.15.
|
||
|
||
### Shared lane
|
||
|
||
park-lab is one lane for both directions ([[passage-confirmation]] "park-lab rig"), so every car
|
||
passes both cameras. The PoC lets **one camera own the lane at a time**. The other camera ignores
|
||
cars until the owner's visit has ended **and** its own zone has been empty once. Without that
|
||
second condition, the car just handled would start a new visit there, with a new open. On the
|
||
drive the far camera ignored the car every time, and no double open happened after the fix.
|
||
|
||
### Plates
|
||
|
||
Plate reading, what was measured about it, and the day and night trials of 2026-11-22 have their
|
||
own page: [[zone-anpr-plate-trials]]. In short:
|
||
|
||
- the plate reads only on a short stretch of the approach, and is not needed for the verdict;
|
||
- the hi-res still is the main reader, the stream frames a faster and weaker second source;
|
||
- on a wet night, 5 plates were decided in 11 entry visits, 2 of them wrong;
|
||
- a pass was judged abandoned that night, and two fixes followed (above, "Since the first build").
|
||
|
||
### The exit camera is out (user, 2026-11-21)
|
||
|
||
The user's verdict: *"Fuck the exit, it's flawed. The barrier interferes with the camera image when
|
||
it's open."*
|
||
|
||
- The boom swings through the exit camera's view when it rises. This was first seen in the
|
||
2026-11-19 recordings on [[passage-confirmation]].
|
||
- The exit line is also drawn off the cars' path.
|
||
- Exit verdicts were wrong on 2 of 3 drives.
|
||
- **On park-lab the entry camera alone judges the crossing in both directions:** it saw drive-ins
|
||
as A → B and drive-outs as "other direction". The exit camera is not used for crossing
|
||
verdicts. Whether it still opens R1 or reads plates for drive-outs is not yet decided.
|
||
|
||
## Still open
|
||
|
||
Deferred by the user on 2026-11-22. The work list, with the evidence for each item, is on
|
||
[[vision-hardening]]. The points that are the user's to rule on:
|
||
|
||
- **A car the detector loses inside the zone:** no close (the code's default) or a close
|
||
(`close_on_lost`, on at park-lab).
|
||
- **The exit camera on park-lab:** it still opens R1 and cannot close.
|
||
- **R1 on known plates only,** which is the real design. The PoC opens for any car.
|
||
|
||
Before R2 is used anywhere else, the preconditions on [[passage-confirmation]] still stand: the
|
||
interlock checked with a meter, the `DET`/`PHO` reversal proven on the unit
|
||
([[zkteco-cmp200-barrier]]), and [[barrier-not-a-door]] revised. The Dingtian "Mutually
|
||
Exclusive" mode does not replace the wiring.
|