4d1d245680
Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only) although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as unresolved with the EM4100 test that settles it (open question #18). Phone taps give a random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink answering the push with the SDK verdict and Connection: close. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
256 lines
17 KiB
Markdown
256 lines
17 KiB
Markdown
---
|
||
type: reference
|
||
tags: [parking, runbook, installation, devices, network, field]
|
||
sources: []
|
||
updated: 2026-09-09
|
||
---
|
||
|
||
# Site device installation — know it BEFORE you are standing in the booth
|
||
|
||
A field runbook: for every device we deploy, its **factory address and credentials**, the **tool**
|
||
you need, **what the app configures by itself** at assign time versus **what must be done by hand on
|
||
the device**, and the **traps already paid for** on park-buzi and the lab. The [[appliance-provisioning]]
|
||
runbook covers the booth PC (OS, disk, Docker, Periphery); this page covers everything plugged into
|
||
it. Written 2026-09-09 after an evening lost to a printer whose factory address nobody had written
|
||
down ([[k200l-printer]]).
|
||
|
||
Rule of thumb that explains most of this page: **every field device ships on its own private
|
||
subnet with DHCP off, and none of them announce themselves.** You bring a laptop that can take a
|
||
second static address, you put it on the device's factory subnet, you move the device to the site
|
||
plan, and only then does anything else see it.
|
||
|
||
## Before leaving the office
|
||
|
||
**Bring**
|
||
|
||
- A laptop with an Ethernet port and the right to add a **second static IPv4 address** to it
|
||
(Windows: adapter → IPv4 → Advanced → add). Under WSL, remember the source-address bug
|
||
([[wsl-dev-networking]]): after adding a temporary address, `ping` may work while HTTP times out.
|
||
- The Dingtian reader tool **`QRCode_v1_6_5.exe`** (Windows) — the only way to set a DT-008's IP,
|
||
server target, prefixes and symbologies. A browser is enough for everything else.
|
||
- Patch cables, a USB A–B cable (printers), the site's **address plan** (below) filled in, the
|
||
app **admin** password, and a fresh Komodo **onboarding key** if the booth PC is new
|
||
([[appliance-provisioning]] §7a).
|
||
- The **serials** if already known: DT-008 `cjihao` (on the reader's label / in the tool), camera
|
||
MAC/serial, printer model (label on the bottom — the K200L's own web UI calls it "POS-80").
|
||
|
||
**Address plan** — the device VLAN ([[network-isolation]]) is `10.0.10.0/24` on both sites so far,
|
||
**every device static, DHCP off everywhere**. The convention from park-buzi / park-lab:
|
||
|
||
| Address | Device | Factory address it came from |
|
||
| --- | --- | --- |
|
||
| 10.0.10.1 | VLAN gateway (switch/router) | — |
|
||
| 10.0.10.5 | [[dingtian-relay]] board (barriers + inputs) | `192.168.1.100` |
|
||
| 10.0.10.7 / .8 | [[dingtian-dt008-reader]] entry / exit (**unique IP each**) | `192.168.1.99` |
|
||
| 10.0.10.9 | entry-dispenser printer (park-buzi: Cashino KP-300H) | *not recorded — fill in* |
|
||
| 10.0.10.10 | booth-receipt printer (park-buzi: [[rongta-printer]]) | *not recorded — fill in* |
|
||
| 10.0.10.11 / .7 (lab) | [[k200l-printer]] | `192.168.123.100` |
|
||
| 10.0.10.12 / .13 | [[lpr-camera]] entry / exit (Hikvision DS-2CD1047G3H-LIU) | `192.168.1.64` (Hikvision default; needs activation) |
|
||
| 10.0.10.203 | the booth PC on the device VLAN (**the `backendIp` every device pushes to**) | — |
|
||
|
||
Fill the real numbers into the site record before you drive; the wizard asks for the booth's push
|
||
address once and writes it into the Dingtian and the cameras.
|
||
|
||
## 1. Dingtian relay board (DT-R004 family) — barriers, button, radar
|
||
|
||
**Factory:** IP `192.168.1.100`, web UI on port 80, login `admin` / `admin`, UDP `60000` (binary) /
|
||
`60001` (string), multicast discovery `224.0.2.11:60000`. See [[dingtian-relay]].
|
||
|
||
**By hand, on the device (browser at its factory address):** set the site IP / mask / gateway in
|
||
the Network page and reboot. That is the only thing you *must* do by hand. Optional but recommended:
|
||
in the web UI **disable the UDP2 "string" protocol** (a password-less relay-fire path); the app's
|
||
harden step tries to disable it and **warns if the device refused** — then do it here.
|
||
|
||
**Wiring:** button on **I1** (NO contact to GND, idles HIGH, pulls LOW on press); radar dry contact
|
||
on **I2**; barrier operator's open input on **relay 1** (entry) and **relay 2** (exit); a spare relay
|
||
for the entry button lamp ([[button-light-indicator]]). One board can carry both barriers; two
|
||
distant barriers = two boards ([[entry-exit-points]]).
|
||
|
||
**What the wizard does on assign** ([[first-run-setup]], [[device-input-flow]]): finds the board by
|
||
multicast ("Scan for controllers" — laptop/booth must share the L2 segment), checks and clears
|
||
`input_link_relay` (factory default auto-fires a relay from its input — the app must decide, not the
|
||
board), sets a random **relay password** (UDP binary), disables every other control channel, rotates
|
||
the web login, and writes the **input push** URL + per-device Digest credentials so button/radar
|
||
edges reach the booth PC. You enter the relay map (which relay is entry/exit/both) and the inputs
|
||
(button → its relay; radar → `presence`, `activeLow` if it idles opposite the button —
|
||
[[hikvision-radar]]).
|
||
|
||
**Traps**
|
||
|
||
- The HTTP CGI API is **unauthenticated** on this firmware; `admin/admin` gates only the web page.
|
||
Never enable `session_en` — it bricks the config API and only a **factory reset** recovers. The
|
||
VLAN is the boundary, not the login ([[dingtian-relay]] §Hardening).
|
||
- A relay password mismatch shows as **"offline despite ping"**: the status query is answered only
|
||
with the right password. Re-assign / re-enter the relay password in the device form.
|
||
- "Relay test" in Setup pulses real hardware and signs a ledger event — use it to prove wiring,
|
||
once per relay.
|
||
|
||
## 2. Dingtian DT-008 QR + RFID readers
|
||
|
||
**Factory:** IP `192.168.1.99`; no web UI — everything is set with **`QRCode_v1_6_5.exe`** over the
|
||
network. See [[dingtian-dt008-reader]].
|
||
|
||
**By hand, in the tool, per reader:**
|
||
|
||
1. **Unique device IP** (`.7` entry, `.8` exit). Two readers on one IP was the 2026-06-18
|
||
"wrong barrier" incident — scans land on the wrong device row.
|
||
2. **Server IP** = the booth PC (`10.0.10.203`), **server port** = the booth's HTTP port (80 behind
|
||
the prod proxy); "server language" can stay whatever it is (php/jsp/asp/aspx/cgi are all
|
||
served — the reader GETs `/qa/mcardsea.<ext>`).
|
||
3. **Output prefixes:** `QRCode Output Prefix` = `Q:`, `Card Output Prefix` = `K:` (channel
|
||
tagging — a printed clone of a card cannot pass as the card).
|
||
4. **Card Input format = `6H`** (defines the UID shape enrolled; changing it later orphans every
|
||
card).
|
||
5. **Symbologies: QR + Code128 only**, minimum decode length ≥ 10, checksums on — otherwise low
|
||
sun through the striped arm produces phantom 6-digit reads (park-buzi, July).
|
||
6. Note the **serial (`cjihao`)** — the wizard binds the reader by serial, not by IP.
|
||
|
||
**In the wizard:** add the reader with its serial, bind it to the controller relay it sits at
|
||
(direction is inherited from the relay). **Verify:** scan a card — the server log shows
|
||
`READ serial=… → device=… verdict=… dir=…`; the reader beeps **twice** on accept, once on refuse,
|
||
and only after the server's reply (no reply = no beep, the scan still happened).
|
||
|
||
**Trap:** a factory reset or a swapped unit silently loses items 3–5. Re-apply all of them.
|
||
|
||
**Trap (2026-09-17): two DT-008 units read disjoint card sets.** park-buzi's units (`H05M…`)
|
||
read the site's 125 kHz cards and the fresh lab unit (`HC002721`) reads only 13.56 MHz cards,
|
||
although the box leaflet claims both. Batch variant, a dead 125 kHz front end, or a non-EM 125 kHz
|
||
card format — unresolved. Rule until it is: **test a replacement reader against the site's actual
|
||
cards before it ships**, and record the site's card technology. Quick sort of a card: an NFC phone
|
||
detects 13.56 MHz, cannot see 125 kHz. Details: [[dingtian-dt008-reader]] §"Two units, two card
|
||
sets".
|
||
|
||
**Identify what a reader can read — before it ships (2026-09-17).** Keep a **reference kit** in the
|
||
lab: one known EM4100 125 kHz fob, one known Mifare Classic (M1) card, and a phone with NFC. Tap all
|
||
three on the unit with the tool's log pane open (or [[dingtian-dt008-reader]] §Bench sink): a line
|
||
per tap = that technology decodes. The phone always beeps on a 13.56 MHz unit with a random `08…`
|
||
id (never a credential, but proves the 13.56 MHz radio). Then tap **the site's own cards**. Write
|
||
the result on the site record next to the serial (`reads: EM4100 | M1 | both`). Serial families are
|
||
only a hint (`H05M…` read park-buzi's 125 kHz cards, `HC…` did not); the vendor can confirm from a
|
||
serial. A unit that fails the site's cards does not leave the lab.
|
||
|
||
**Parameters per card technology** — identical except one field:
|
||
|
||
| | 125 kHz site (park-buzi today) | 13.56 MHz site |
|
||
| --- | --- | --- |
|
||
| Card Input format | **`6H`** (what park-buzi's cards are enrolled with — never change on a live site) | **`8H`** preferred: the native UID is 4 bytes, `6H` drops one and two cards can collide — confirm `8H` on the lab unit before the first enrolment ([[open-questions]] #18) |
|
||
| Output prefixes | `Q:` / `K:` | `Q:` / `K:` |
|
||
| Output type / server | HTTP, booth IP, booth HTTP port | same |
|
||
| Buzzer | On (the operator hears accept/refuse) | On |
|
||
| Symbologies | QR + Code128 only | same |
|
||
| Card stock | EM4100 (or whatever the reference test showed) — do not mix | Mifare Classic UID-based; note that a phone is never a card |
|
||
|
||
A site is one technology: once cards are enrolled the reader batch, the input format and the
|
||
card stock are frozen together. Migrating means re-enrolling every credential.
|
||
|
||
**The tool's Setting tab (v1.6.5, seen 2026-09-17):** *Search device* lists units by serial; *Get
|
||
parameter* loads one. *Network parameter*: IP / Netmask / Gateway / DNS1 / DNS2, DHCP (Static IP),
|
||
**Server address / Server Port / HTTP Server Language**, its own *Set* button. *Format parameter*:
|
||
Output type `HTTP`, **Card Input format** (`6H`), QRCode Output format/prefix/suffix, **Card Output
|
||
format/prefix/suffix** (prefix fields are where `Q:` / `K:` go), serial baud/bits greyed out under
|
||
HTTP, Low/High Pulse, its own *Set*. *External parameter*: Restart interval (12 h), Work mode
|
||
(Normal), **Buzzer On/Off**, Scan code fill light, its own *Set*. Each group is written by **its own
|
||
Set button** — setting the network and forgetting the format *Set* is easy. The log pane at the bottom
|
||
echoes every card read by the tool (`… A238BC`), which is the quickest "did the radio see it" check.
|
||
The *Test device* tab is the read monitor. Symbology selection was not found on this tab — locate it
|
||
on the *Test device* tab or in a newer tool before relying on item 5.
|
||
|
||
## 3. Hikvision camera (DS-2CD1047G3H-LIU, AcuSense) — ANPR + snapshots
|
||
|
||
**Factory:** `192.168.1.64`, **inactive** until a password is set on first boot (browser at that
|
||
address or the SADP tool); after activation the login is `admin` / the password you chose. Site
|
||
convention so far: `admin` / `admin123` on the first units (change per site and record it). See
|
||
[[lpr-camera]].
|
||
|
||
**By hand, on the camera:**
|
||
|
||
1. Activate, set the site IP, disable DHCP. Time: NTP off-site is unavailable — the app re-syncs
|
||
the camera clock from the booth at every offline→ready edge ([[clock-integrity]]).
|
||
2. **Streams:** the snapshot the app pulls MUST come from the **sub stream** (`102`) — the main
|
||
stream's ISAPI snapshot returns **503 instantly, always, on this model**. Set the sub stream to
|
||
the highest resolution the camera allows.
|
||
3. **Event push:** Event → Motion Detection with the AcuSense **Detection Target = Vehicle** filter
|
||
ON, "Notify Surveillance Center" on, then Alarm Settings → **Alarm Server** →
|
||
`http://10.0.10.203/api/devices/hikvision/<deviceId>/event`. The `deviceId` exists only after
|
||
the wizard assign, so: **assign first, then come back to the camera**. Digest user/password if
|
||
the firmware allows it (the wizard shows them).
|
||
4. "Enable Hikvision-CGI" is a different legacy surface — **not** needed for ISAPI.
|
||
5. **Close the web UI / live view when done.** The camera has few connection slots; a browser left
|
||
open makes every snapshot pull 503 "Device Busy" ([[lpr-camera]] §503).
|
||
|
||
**In the wizard:** driver `hikvision`, host, `admin` password, channel 1, **stream = Sub**, ANPR on,
|
||
bind to the relay at that barrier, `alarmPushEnabled` on.
|
||
|
||
**Verify, do not assume:** drive a car through and look at `GET /api/events` (or the log) for an
|
||
alarm with `targetType=vehicle`. A camera configured for push that has sent **zero** alarms is
|
||
broken on its side: pull its *Diagnose Information*; `Main Db is broken` means a corrupt config
|
||
database → **factory reset**, then redo 1–3 (the Vehicle target filter defaults OFF after a reset).
|
||
Point the Alarm Server at a dumb HTTP sink on the laptop if you need to see the verbatim body
|
||
([[lpr-camera]] §"auto-enter but not auto-exit").
|
||
|
||
## 4. Radar (vehicle presence at the entry barrier)
|
||
|
||
A dry-contact sensor into a Dingtian input, nothing on the network. Check with the board's input
|
||
status (`00` query → `relays:inputs`) whether it **idles HIGH or LOW**; if it idles opposite the
|
||
button, set `activeLow` on that input in the wizard, or the gate inverts (tickets only when the
|
||
lane is empty). It is advisory: it gates the button, it never opens anything ([[hikvision-radar]],
|
||
[[entry-double-press]]).
|
||
|
||
## 5. Printers — three models, one byte stream, different status
|
||
|
||
All print the same ESC/POS bytes over **raw TCP 9100** or **USB (`/dev/usb/lpN`)**; what differs
|
||
is whether the app can see paper/cover state ([[printer-status-monitoring]],
|
||
[[printer-usb-transport]]). Roles: **entry-dispenser** outside at the lane, **booth-receipt**
|
||
inside (receipts, subscription cards, Z-reports, and the backup for entry tickets), **wash-desk**
|
||
if the site has a Car Wash ([[printer-roles-failover]]). Higher `failoverRank` = tried first.
|
||
|
||
| Model | Factory network | Config UI | App driver | Live status |
|
||
| --- | --- | --- | --- | --- |
|
||
| [[k200l-printer]] (Xprinter/ICS K200L, "POS-80" board; **the park-buzi unit**) | `192.168.123.100/24`, DHCP off | browser, port 80, no login: Configuration → fixed IP → Save → Restart | **`k200l`** | over LAN: cover / paper / cutter / off-line from `/prt_status.htm`; over USB: reachability only |
|
||
| [[rongta-printer]] (RP-series) | *not recorded — fill in* | status page `/prn_stat.htm` on port 80 | `rongta` | over LAN: full; USB: reachability |
|
||
| Cashino KP-300H | *not recorded — fill in* | *not recorded* | `escpos` (generic) | reachability only, by design — no trustworthy status source |
|
||
|
||
**Prefer LAN over USB** wherever a cable can reach: the booth sees a real amber "cover open, paper
|
||
out" while a roll is changed, and the `usblp` path (udev rule, node renumbering, the park-buzi
|
||
"offline after reload" mystery) drops out of the picture. USB needs the appliance's `usblp` +
|
||
udev rule ([[printer-usb-transport]] §Provisioning) and the printer shows up as `/dev/usb/lpN`,
|
||
numbered by plug order.
|
||
|
||
**Verify:** the wizard's "Test" only *probes* (opens the port / the device node) — it prints
|
||
nothing. Print something real: a subscription with a QR credential auto-prints its card and has a
|
||
**Reprint card** button; a payment prints a receipt; a wash till prints slips. Check the Cashino's
|
||
barcode with a real ticket (the KP-300H garbled overflowing barcodes until the geometry fix).
|
||
|
||
## 6. Order of work on site
|
||
|
||
1. Address plan on paper; VLAN ports patched; booth PC up with its device-VLAN address.
|
||
2. Dingtian: factory address → site address (browser) → wire button, radar, barriers.
|
||
3. Wizard: **controllers first** (the relay map + inputs); "Relay test" each barrier.
|
||
4. Readers: tool (IP, server, prefixes, format, symbologies) → wizard (serial, bind) → scan test.
|
||
5. Cameras: activate → IP → sub stream → wizard assign → Alarm Server + Vehicle target → drive-through
|
||
test → close the browser.
|
||
6. Printers: site address → wizard (role, rank) → print a card.
|
||
7. Walk-through: button + radar → ticket; QR entry then exit; RFID; a subscriber's plate at the
|
||
camera; pay at the booth → receipt → exit; paper reload on each printer while watching the
|
||
footer.
|
||
8. Record in the site record: every IP, serial, camera password, printer model, which relay is
|
||
which, photos of the labels. Remove the temporary laptop addresses. Log out of every device UI.
|
||
|
||
## Gaps to fill next time you hold the hardware
|
||
|
||
- Factory address and configuration tool of the **Cashino KP-300H** and the **Rongta RP** units
|
||
(both still unknown here).
|
||
- Where in `QRCode_v1_6_5.exe` the **symbologies** are selected (the Setting tab has no such field;
|
||
the IP / server / prefix fields are now described in §2).
|
||
- The **card technology** each site uses and which reader batch reads it, on the site record next to
|
||
the serial; and the result of the EM4100 test on the lab unit.
|
||
- Whether the camera activation was done with SADP or the browser at park-buzi, and the per-site
|
||
camera password location.
|
||
- Where the **site record** lives (a page per site under `wiki/entities/`? — park-buzi and park-2
|
||
have none yet; the Komodo stack env is the closest thing).
|
||
|
||
Related: [[appliance-provisioning]] · [[first-run-setup]] · [[device-registry]] ·
|
||
[[network-isolation]] · [[entry-exit-points]] · [[dingtian-relay]] · [[dingtian-dt008-reader]] ·
|
||
[[lpr-camera]] · [[hikvision-radar]] · [[k200l-printer]] · [[rongta-printer]] ·
|
||
[[printer-usb-transport]] · [[wsl-dev-networking]]
|