4593a397dd
Build & push images / images (push) Successful in 3m25s
The dahua driver decremented the wizard's channel on the belief the CGI is 0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17) snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620 JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts. DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift limit, writes setCurrentTime with the host's naive local wall time (no offset): the OSD burned into snapshots must match the booth clock; the camera's tz/DST config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no write. The device monitor picks it up via isClockSyncable unchanged. Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo, TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout, unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua paragraph; index + log. The server-side attach-stream subscriber is not built.
144 lines
9.1 KiB
Markdown
144 lines
9.1 KiB
Markdown
---
|
||
type: entity
|
||
tags: [parking, hardware, camera, dahua, snapshot, events, bench]
|
||
sources: []
|
||
updated: 2026-09-17
|
||
---
|
||
|
||
# Dahua IPC-HFW2549T-AS-IL — the lab bench unit (inspected 2026-09-17)
|
||
|
||
A 5 MP Dahua WizSense bullet (`IPC-HFW2549T-AS-IL-0360B`, 3.6 mm, "IL" = smart dual illuminators),
|
||
firmware **`V2.880.0000000.22.R`, build 2026-05-14**, serial `9J0E4EFPAGECB23`, MAC
|
||
`fc:5f:49:48:42:ac`, processor SSC378Q. Sits on the bench at `10.0.10.11`, login `admin` / the lab
|
||
password. **It is not an ANPR camera** — plates come from the host-side [[opencv-anpr-service]]
|
||
off its snapshot, exactly as with the Hikvision units. Everything below was read off the unit
|
||
over its CGI with `curl --digest`; nothing was written to it.
|
||
|
||
**It is not factory-fresh.** Hostname `DAHUA_PORTA_KRYESORE` ("main gate"), an Alarm Server already
|
||
pointed at `10.7.8.9:8888`, DNS `8.8.8.8`, SMD tuned to vehicles only — this unit was configured
|
||
for a gate somewhere before it reached the bench. Treat its settings as inherited, not defaults.
|
||
|
||
## What the CGI surface gives us
|
||
|
||
| Need | Endpoint (all HTTP Digest, port 80; 443 is **off**) | Result on this unit |
|
||
| --- | --- | --- |
|
||
| identity | `magicBox.cgi?action=getSystemInfo` / `getSoftwareVersion` / `getSerialNo` / `getVendor` | model, firmware, serial, `vendor=Dahua` |
|
||
| snapshot | `snapshot.cgi?channel=1` | 200, `image/jpeg`, **2880×1620**, ~270 KB, ~0.5 s |
|
||
| snapshot channel `0` / `2` | same | **400** — the channel index is **1-based**; `subtype=1` is ignored (still 2880×1620) |
|
||
| clock read | `global.cgi?action=getCurrentTime` | `result=2026-09-17 09:03:50` |
|
||
| clock write | `global.cgi?action=setCurrentTime&time=YYYY-MM-DD%20HH:MM:SS` | 200 `OK`; read-back matches within 1 s (**verified**, now the Dahua clock-sync) |
|
||
| events | `eventManager.cgi?action=attach&codes=[All]&heartbeat=5` | 200, `multipart/x-mixed-replace`, a `Heartbeat` part every N s, event parts in between |
|
||
| event caps | `eventManager.cgi?action=getCaps` | snapshot/record/mail/alarm-out linkage; no HTTP push cap |
|
||
| streams | RTSP 554 `cam/realmonitor?channel=1&subtype=0` / `1` | **H.265** Main 2880×1620 @ 20 fps; sub 704×576 @ 20 fps (probed with ffprobe) |
|
||
| ports | 80 (HTTP), 554 (RTSP), 37777 (Dahua SDK/DHIP) open; 443, 37778, 5000, 8000 closed | |
|
||
|
||
### Snapshot: the driver decremented the channel — this unit said no (fixed 2026-09-17)
|
||
|
||
`dahuaDriver` (`packages/devices/src/drivers/camera.ts`) builds
|
||
`/cgi-bin/snapshot.cgi?channel=${ch-1}` on the note "Dahua channels are 0-based". On this firmware
|
||
`channel=0` → **HTTP 400**, `channel=1` → the JPEG. Dahua's HTTP API numbers `snapshot.cgi` and
|
||
`realmonitor` channels from 1 (only the `configManager` *tables* are 0-indexed — the usual source
|
||
of the confusion). So an admin who enters "channel 1" in the wizard gets a permanent **degraded
|
||
"HTTP 400"** from `healthCheck()` and no snapshot ever. The Dahua driver was never run against
|
||
hardware before today ([[lpr-camera]] §Verified only covers Hikvision). **Fixed the same day**: the
|
||
driver now sends the channel as entered (clamped to ≥1) and `camera.test.ts` pins the URL. The
|
||
fixed driver was then run against this unit: `healthCheck` → ready (≈256 KB), `captureSnapshot` →
|
||
`image/jpeg`, 273 KB, JPEG magic.
|
||
|
||
The snapshot always comes off the **main** stream at full resolution — there is no per-stream
|
||
snapshot as on Hikvision, and `subtype` on `snapshot.cgi` is ignored. Fine for us: the app
|
||
re-encodes to 1280 px on capture ([[snapshot-storage-optimization]]) and the recognizer keeps the
|
||
full frame.
|
||
|
||
### Events: Dahua PULLS-with-a-held-socket, it does not HTTP-POST
|
||
|
||
Dahua has an "Alarm Server" too (`configManager.cgi?action=getConfig&name=AlarmServer`), but its
|
||
protocol is **`DAHUA`** (proprietary, port 8888) — not the Hikvision-style HTTP POST that
|
||
`routes/hikvision-alarm.ts` consumes. The HTTP way to get events is the **subscription stream**:
|
||
the host opens `eventManager.cgi?action=attach&codes=[SmartMotionVehicle,CrossLineDetection,…]&heartbeat=5`
|
||
and keeps it open; the camera writes one multipart part per event (`Code=…;action=Start|Stop;index=…`)
|
||
and a `Heartbeat` part every 5 s. Verified on the bench: the stream stays up, heartbeats arrive,
|
||
Digest auth applies to the attach. This inverts the Hikvision model:
|
||
|
||
- the camera never needs to know the booth's address — no `pushesToBackend`, no "assign first,
|
||
then go back to the camera" step, no source-IP guard, and the WSL mirrored-mode source-IP
|
||
problem does not exist;
|
||
- the **server** owns the connection: reconnect with backoff, treat a missing heartbeat as
|
||
camera-offline, one long-lived socket per Dahua camera;
|
||
- vehicle events come from **SMD** (`SmartMotionDetect`: `Enable=true`, `ObjectTypes.Vehicle=true`,
|
||
`Human=false` on this unit — inherited, and exactly the "Detection Target = Vehicle" the Hikvision
|
||
runbook step asks for) → code `SmartMotionVehicle`; tripwire/intrusion (`CrossLineDetection`,
|
||
`CrossRegionDetection`) with `ObjectTypes=Vehicle` are the IVS equivalents, **none configured**
|
||
on this unit (only disabled FaceDetection and HeatMap rules exist).
|
||
|
||
**Verbatim event parts captured** on a 25-minute `codes=[All]` listen (bench motion + the clock
|
||
write below). Each part is `Content-Type: text/plain` with a `Code=…;action=…;index=…;data={JSON}`
|
||
body:
|
||
|
||
```
|
||
Code=VideoMotion;action=Start;index=0;data={
|
||
"EventID" : 31927,
|
||
"Id" : [ 0 ],
|
||
"RealUTC" : 1789634136,
|
||
"RegionName" : [ "Region1" ],
|
||
"SmartMotionEnable" : true,
|
||
"WithSnap" : true
|
||
}
|
||
Code=VideoMotion;action=Stop;index=0;data={ …same EventID… }
|
||
Code=VideoMotionInfo;action=State;index=0;data={ "RealUTC" : 1789634137, "WithSnap" : false }
|
||
Code=TimeChange;action=Pulse;index=0;data={
|
||
"BeforeModifyTime" : "17-09-2026 09:35:51",
|
||
"ModifiedTime" : "17-09-2026 10:35:49",
|
||
"RealUTC" : 1789637749,
|
||
"WithSnap" : false
|
||
}
|
||
```
|
||
|
||
- `action=Start` / `Stop` with a shared `EventID` is the busy/free edge (the Hikvision
|
||
`active`/`inactive` equivalent); `VideoMotionInfo State` is a per-second chatter part to ignore.
|
||
- The motion arrived as plain `VideoMotion` with `SmartMotionEnable: true`, **not** as
|
||
`SmartMotionVehicle` — whether the SMD filter suppresses `VideoMotion` for non-vehicles, or only
|
||
adds the `SmartMotion*` codes on top, is **unconfirmed** (nobody drove a car past the bench).
|
||
Subscribe to both and log which fires before gating anything on it.
|
||
- **`RealUTC` is the camera's *belief* of UTC, i.e. its wall time minus its configured offset.**
|
||
After the clock write it read 09:35:49 for a real 08:35:49 UTC (UTC+1, DST off). Never use it
|
||
as an absolute time — stamp events on receipt from the booth clock, as the Hikvision route does.
|
||
- `TimeChange` is emitted for our own clock sync; harmless, but filter it from any "activity" view.
|
||
|
||
### Clock: one hour behind, NTP off — clock-sync built the same day
|
||
|
||
`getCurrentTime` returned 09:03 while the bench wall clock read 10:03 CEST: `NTP.Enable=false`
|
||
(address `time.windows.com`, unreachable on an isolated VLAN anyway), `NTP.TimeZone=1` (Belgrade)
|
||
and **`Locales.DSTEnable=false`**, so the unit runs at UTC+1 year-round. The Hikvision units get
|
||
their clock from the booth at every offline→ready edge ([[clock-integrity]]); until today the
|
||
Dahua driver did not claim `isClockSyncable`. Now `DahuaCamera.syncClock` (camera.ts) reads
|
||
`global.cgi?action=getCurrentTime` (`result=YYYY-MM-DD HH:MM:SS`) and, past the drift limit, writes
|
||
`setCurrentTime&time=<host wall time>` — the **host's naive local wall time, no offset**, because
|
||
what has to match the booth is the OSD burned into every snapshot, not the camera's notion of UTC
|
||
(its tz/DST config is left alone, as on Hikvision). Verified on the bench with the real driver:
|
||
a 2 h-off host time set (drift 7200 → synced), set back, then read as 1 s drift → no write. The
|
||
device monitor picks it up unchanged (it gates on `isClockSyncable`, not on the driver id). A wrong
|
||
DST setting on the camera therefore no longer matters for the evidence trail — only `RealUTC` in
|
||
event bodies stays skewed (above).
|
||
|
||
### Login lockout — the device monitor must never poll with a wrong password
|
||
|
||
`General.LockLoginEnable=true`, `LockLoginTimes=5`, `LoginFailLockTime=300`: five bad Digest
|
||
logins lock `admin` out for 5 minutes. A wizard assignment with a mistyped password, polled every
|
||
few seconds by the device monitor, locks the camera and then **every** login (including the
|
||
browser) fails until the poll stops. Verify the password with one `curl` before assigning; on a
|
||
mysterious "401 then nothing works" wait five minutes.
|
||
|
||
## Bench notes
|
||
|
||
- `10.0.10.11` is the runbook's address for the lab [[k200l-printer]] ([[site-device-installation]]
|
||
§address plan) — the camera has taken it on the bench; keep the two off the wire together or
|
||
move one.
|
||
- The other HTTP APIs newer Dahua firmware carries (`RPC2` JSON, `/onvif/device_service`) were not
|
||
exercised — the CGI above covers everything the app needs.
|
||
- `devVideoInput.cgi?action=getCaps` and `magicBox.cgi?action=getProductDefinition` answer
|
||
"Bad Request" / "Not Implemented" on this firmware.
|
||
|
||
Related: [[lpr-camera]] · [[opencv-anpr-service]] · [[lane-presence-and-anpr-entry]] ·
|
||