feat(devices): DT-008 reader discovery + auto-configuration over the vendor UDP protocol
The Dingtian DT-008's Windows-only config tool speaks a small binary UDP protocol
(reader :24680 unicast get/set, :24582 broadcast search/set-network), reversed in
wiki/raw/dingtian_qr_linux (PROTOCOL.md + dingtian_qr.py, copied to scripts/). Reading
park-2's readers with it from the booth found both in WG26 output mode — the "beeps but
captures nothing" enrolment failure: they never pushed HTTP at all.

The app now speaks the protocol itself (packages/devices dingtian-qr-config.ts, Node dgram,
host-network container) and the dingtian-qr-reader driver uses it:
- discover(): first driver to implement the wizard's Scan capability; rows show serial, IP,
  output mode, current server target, card format, firmware.
- preconditions: output type must be HTTP (fixable — save switches it); typed serial must
  equal the reported one and the reader must answer on UDP (both block the save).
- configureInputPush(): set-network the reader's server to this booth's IP + listen port,
  confirmed by polling (the reader applies it without an ack and is silent for seconds).
- usesPushAuth=false: the scan GET carries no credentials, so no push secret is stored.
- a reader saved without an IP warns instead of failing (legacy vendor-tool setup).

Verified on the bench unit: WG26→HTTP, target 8080→8081→8080, struct byte-identical after.
15 protocol tests against a fake reader + 17 adapter tests. Wiki: device-discovery,
first-run-setup, dingtian-dt008-reader, site-device-installation §2 (SSH procedure; the
"needs a Windows laptop" claim withdrawn), new source page dingtian-qr-linux-tool.
2026-10-08 15:22:33 +02:00

305 lines
21 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
type: reference
tags: [parking, runbook, installation, devices, network, field]
sources: []
updated: 2026-10-08
---
# Site device installation — know it BEFORE you are standing in the booth
A field runbook: for every device we deploy, its **factory address and credentials**, the **tool**
you need, **what the app configures by itself** at assign time versus **what must be done by hand on
the device**, and the **traps already paid for** on park-buzi and the lab. The [[appliance-provisioning]]
runbook covers the booth PC (OS, disk, Docker, Periphery); this page covers everything plugged into
it. Written 2026-09-09 after an evening lost to a printer whose factory address nobody had written
down ([[k200l-printer]]).
Rule of thumb that explains most of this page: **every field device ships on its own private
subnet with DHCP off, and none of them announce themselves.** You bring a laptop that can take a
second static address, you put it on the device's factory subnet, you move the device to the site
plan, and only then does anything else see it.
## Before leaving the office
**Bring**
- A laptop with an Ethernet port and the right to add a **second static IPv4 address** to it
(Windows: adapter → IPv4 → Advanced → add). Under WSL, remember the source-address bug
([[wsl-dev-networking]]): after adding a temporary address, `ping` may work while HTTP times out.
- The Dingtian reader tool **`QRCode_v1_6_5.exe`** (Windows) **or `scripts/dingtian_qr.py`**
(Python 3, runs on the booth itself — see [[dingtian-qr-linux-tool]]) for a DT-008's IP, server
target, output type, prefixes and card format. Symbologies are set in neither (no known path).
A browser is enough for everything else.
- Patch cables, a USB A–B cable (printers), the site's **address plan** (below) filled in, the
app **admin** password, and a fresh Komodo **onboarding key** if the booth PC is new
([[appliance-provisioning]] §7a).
- The **serials** if already known: DT-008 `cjihao` (on the reader's label / in the tool), camera
MAC/serial, printer model (label on the bottom — the K200L's own web UI calls it "POS-80").
**Address plan** — the device VLAN ([[network-isolation]]) is `10.0.10.0/24` on both sites so far,
**every device static, DHCP off everywhere**. The convention from park-buzi / park-lab:
| Address | Device | Factory address it came from |
| --- | --- | --- |
| 10.0.10.1 | VLAN gateway (switch/router) | — |
| 10.0.10.5 | [[dingtian-relay]] board (barriers + inputs) | `192.168.1.100` |
| 10.0.10.7 / .8 | [[dingtian-dt008-reader]] entry / exit (**unique IP each**) | `192.168.1.99` |
| 10.0.10.9 | entry-dispenser printer (park-buzi: Cashino KP-300H) | *not recorded — fill in* |
| 10.0.10.10 | booth-receipt printer (park-buzi: [[rongta-printer]]) | *not recorded — fill in* |
| 10.0.10.11 / .7 (lab) | [[k200l-printer]] | `192.168.123.100` |
| 10.0.10.12 / .13 | [[lpr-camera]] entry / exit (Hikvision DS-2CD1047G3H-LIU) | `192.168.1.64` (Hikvision default; needs activation) |
| 10.0.10.203 | the booth PC on the device VLAN (**the `backendIp` every device pushes to**) | — |
Fill the real numbers into the site record before you drive; the wizard asks for the booth's push
address once and writes it into the Dingtian and the cameras.
## 1. Dingtian relay board (DT-R004 family) — barriers, button, radar
**Factory:** IP `192.168.1.100`, web UI on port 80, login `admin` / `admin`, UDP `60000` (binary) /
`60001` (string), multicast discovery `224.0.2.11:60000`. See [[dingtian-relay]].
**By hand, on the device (browser at its factory address):** set the site IP / mask / gateway in
the Network page and reboot. That is the only thing you *must* do by hand. Optional but recommended:
in the web UI **disable the UDP2 "string" protocol** (a password-less relay-fire path); the app's
harden step tries to disable it and **warns if the device refused** — then do it here.
**Wiring:** button on **I1** (NO contact to GND, idles HIGH, pulls LOW on press); radar dry contact
on **I2**; barrier operator's open input on **relay 1** (entry) and **relay 2** (exit); a spare relay
for the entry button lamp ([[button-light-indicator]]). One board can carry both barriers; two
distant barriers = two boards ([[entry-exit-points]]).
**What the wizard does on assign** ([[first-run-setup]], [[device-input-flow]]): finds the board by
multicast ("Scan for controllers" — laptop/booth must share the L2 segment), checks and clears
`input_link_relay` (factory default auto-fires a relay from its input — the app must decide, not the
board), sets a random **relay password** (UDP binary), disables every other control channel, rotates
the web login, and writes the **input push** URL + per-device Digest credentials so button/radar
edges reach the booth PC. You enter the relay map (which relay is entry/exit/both) and the inputs
(button → its relay; radar → `presence`, `activeLow` if it idles opposite the button —
[[hikvision-radar]]).
**Traps**
- The HTTP CGI API is **unauthenticated** on this firmware; `admin/admin` gates only the web page.
Never enable `session_en` — it bricks the config API and only a **factory reset** recovers. The
VLAN is the boundary, not the login ([[dingtian-relay]] §Hardening).
- A relay password mismatch shows as **"offline despite ping"**: the status query is answered only
with the right password. Re-assign / re-enter the relay password in the device form.
- "Relay test" in Setup pulses real hardware and signs a ledger event — use it to prove wiring,
once per relay.
## 2. Dingtian DT-008 QR + RFID readers
**Factory:** IP `192.168.1.99`; no web UI — everything is set over the network with
**`QRCode_v1_6_5.exe`** (Windows) or **`scripts/dingtian_qr.py`** (any OS; same UDP protocol,
reversed 2026-10 — [[dingtian-qr-linux-tool]]). See [[dingtian-dt008-reader]].
**From the wizard (app builds after 2026-10-08):** add a reader → **Skano LAN-in / Scan the
LAN** lists every DT-008 on the device VLAN with its mode and current server; **Use** fills
serial + IP; **Test** says whether it is in HTTP mode and whether the serial matches; **Save**
switches it to HTTP and points its server at this booth (items 2 and 6 below, done for you).
Items 1, 3, 4, 5 are still manual (IP via `set-network`, prefixes/card format via `set`, both in
`scripts/dingtian_qr.py`; symbologies only in the exe). Needs the reader's IP in the form — with
it blank the save warns and configures nothing.
**By hand (vendor tool, or `scripts/dingtian_qr.py` from the booth), per reader:**
1. **Unique device IP** (`.7` entry, `.8` exit). Two readers on one IP was the 2026-06-18
"wrong barrier" incident — scans land on the wrong device row.
2. **Output type = `HTTP`** (the tool also offers RS232 / WG26 / WG34 / RS485 / USB keyboard /
USB serial — in any of those the reader beeps locally and never contacts the booth), **Server
IP = THIS site's booth** (park-2 is `10.0.10.101`; `10.0.10.203` is the lab — never copy it),
**server port** = the booth's HTTP port (80 behind the prod proxy); "server language" can stay
whatever it is (php/jsp/asp/aspx/cgi are all served — the reader GETs `/qa/mcardsea.<ext>`).
3. **Output prefixes:** `QRCode Output Prefix` = `Q:`, `Card Output Prefix` = `K:` (channel
tagging — a printed clone of a card cannot pass as the card).
4. **Card Input format = `6H`** (defines the UID shape enrolled; changing it later orphans every
card).
5. **Symbologies: QR + Code128 only**, minimum decode length ≥ 10, checksums on — otherwise low
sun through the striped arm produces phantom 6-digit reads (park-buzi, July).
6. Note the **serial (`cjihao`)** — the wizard binds the reader by serial, not by IP.
**In the wizard:** add the reader with its serial, bind it to the controller relay it sits at
(direction is inherited from the relay). **Verify:** scan a card — the server log shows
`READ serial=… → device=… verdict=… dir=…`; the reader beeps **twice** on accept, once on refuse,
and only after the server's reply (no reply = no beep, the scan still happened).
**From the booth, no Windows (2026-10-08):** `get` / `set` are unicast UDP, so they run on the
booth host over SSH (Python 3 is on every booth; the server container has none):
```
scp scripts/dingtian_qr.py <booth>:/tmp/ && ssh <booth> python3 -I /tmp/dingtian_qr.py get 10.0.10.7
ssh <booth> python3 -I /tmp/dingtian_qr.py set 10.0.10.7 --output-type 3 # item 2: HTTP mode
```
`get` prints every field above by name (`output_type`, `server`, `server_port`, `card_input_format`,
`qr_prefix`, `card_prefix`…). `set` changes only the fields given and re-sends the rest as read.
Only `discover` / `set-network` need the L2 broadcast (run them on the booth, not across Netbird).
**Trap:** a factory reset or a swapped unit silently loses items 3–5. Re-apply all of them.
**Trap (park-2, 2026-10-08): "it beeps, so it works" is false.** Enrolling a card failed on both
readers although each beeped. The booth log held **zero** `/qa/mcardsea` requests over 21 h and the
capture window saw only the form's own polls: the readers never contact the booth at all. A beep
without a `READ` line in the log means the reader is **not in HTTP mode or points at another
server** — fix it on the reader (item 2), nothing in the app or the wizard can. Diagnose in one
command on the booth: `docker logs <server> --since 1h 2>&1 | grep -c mcardsea` while a card is
presented — `0` = reader-side; then **read the reader itself** with `dingtian_qr.py get` (above).
park-2's answer: both readers `output_type = WG26` (server `10.0.10.101:3000`, JSP, 6H, no
prefixes) — they were left in Wiegand mode at install, so every scan went to a Wiegand line
nobody is listening on. (Port 3000 is fine: the host-net server listens there directly; 80 via
Caddy works too.) Fix = `set <ip> --output-type 3` per reader, then re-run the enrolment.
**Trap (2026-09-17): two DT-008 units read disjoint card sets.** park-buzi's units (`H05M…`)
read the site's 125 kHz cards and the fresh lab unit (`HC002721`) reads only 13.56 MHz cards,
although the box leaflet claims both. Batch variant, a dead 125 kHz front end, or a non-EM 125 kHz
card format — unresolved. Rule until it is: **test a replacement reader against the site's actual
cards before it ships**, and record the site's card technology. Quick sort of a card: an NFC phone
detects 13.56 MHz, cannot see 125 kHz. Details: [[dingtian-dt008-reader]] §"Two units, two card
sets".
**Identify what a reader can read — before it ships (2026-09-17).** Keep a **reference kit** in the
lab: one known EM4100 125 kHz fob, one known Mifare Classic (M1) card, and a phone with NFC. Tap all
three on the unit with the tool's log pane open (or [[dingtian-dt008-reader]] §Bench sink): a line
per tap = that technology decodes. The phone always beeps on a 13.56 MHz unit with a random `08…`
id (never a credential, but proves the 13.56 MHz radio). Then tap **the site's own cards**. Write
the result on the site record next to the serial (`reads: EM4100 | M1 | both`). Serial families are
only a hint (`H05M…` read park-buzi's 125 kHz cards, `HC…` did not); the vendor can confirm from a
serial. A unit that fails the site's cards does not leave the lab.
**Parameters per card technology** — identical except one field:
| | 125 kHz site (park-buzi today) | 13.56 MHz site |
| --- | --- | --- |
| Card Input format | **`6H`** (what park-buzi's cards are enrolled with — never change on a live site) | **`8H`** preferred: the native UID is 4 bytes, `6H` drops one and two cards can collide — confirm `8H` on the lab unit before the first enrolment ([[open-questions]] #18) |
| Output prefixes | `Q:` / `K:` | `Q:` / `K:` |
| Output type / server | HTTP, booth IP, booth HTTP port | same |
| Buzzer | On (the operator hears accept/refuse) | On |
| Symbologies | QR + Code128 only | same |
| Card stock | EM4100 (or whatever the reference test showed) — do not mix | Mifare Classic UID-based; note that a phone is never a card |
A site is one technology: once cards are enrolled the reader batch, the input format and the
card stock are frozen together. Migrating means re-enrolling every credential.
**The tool's Setting tab (v1.6.5, seen 2026-09-17):** *Search device* lists units by serial; *Get
parameter* loads one. *Network parameter*: IP / Netmask / Gateway / DNS1 / DNS2, DHCP (Static IP),
**Server address / Server Port / HTTP Server Language**, its own *Set* button. *Format parameter*:
Output type `HTTP`, **Card Input format** (`6H`), QRCode Output format/prefix/suffix, **Card Output
format/prefix/suffix** (prefix fields are where `Q:` / `K:` go), serial baud/bits greyed out under
HTTP, Low/High Pulse, its own *Set*. *External parameter*: Restart interval (12 h), Work mode
(Normal), **Buzzer On/Off**, Scan code fill light, its own *Set*. Each group is written by **its own
Set button** — setting the network and forgetting the format *Set* is easy. The log pane at the bottom
echoes every card read by the tool (`… A238BC`), which is the quickest "did the radio see it" check.
The *Test device* tab is the read monitor. Symbology selection was not found on this tab — locate it
on the *Test device* tab or in a newer tool before relying on item 5.
## 3. Hikvision camera (DS-2CD1047G3H-LIU, AcuSense) — ANPR + snapshots
**Factory:** `192.168.1.64`, **inactive** until a password is set on first boot (browser at that
address or the SADP tool); after activation the login is `admin` / the password you chose. Site
convention so far: `admin` / `admin123` on the first units (change per site and record it). See
[[lpr-camera]].
**By hand, on the camera:**
1. Activate, set the site IP, disable DHCP. Time: NTP off-site is unavailable — the app re-syncs
the camera clock from the booth at every offline→ready edge ([[clock-integrity]]).
2. **Streams:** the snapshot the app pulls MUST come from the **sub stream** (`102`) — the main
stream's ISAPI snapshot returns **503 instantly, always, on this model**. Set the sub stream to
the highest resolution the camera allows.
3. **Event push:** Event → Motion Detection with the AcuSense **Detection Target = Vehicle** filter
ON, "Notify Surveillance Center" on, then Alarm Settings → **Alarm Server** →
`http://10.0.10.203/api/devices/hikvision/<deviceId>/event`. The `deviceId` exists only after
the wizard assign, so: **assign first, then come back to the camera**. Digest user/password if
the firmware allows it (the wizard shows them).
4. "Enable Hikvision-CGI" is a different legacy surface — **not** needed for ISAPI.
5. **Close the web UI / live view when done.** The camera has few connection slots; a browser left
open makes every snapshot pull 503 "Device Busy" ([[lpr-camera]] §503).
**In the wizard:** driver `hikvision`, host, `admin` password, channel 1, **stream = Sub**, ANPR on,
bind to the relay at that barrier, `alarmPushEnabled` on.
**Verify, do not assume:** drive a car through and look at `GET /api/events` (or the log) for an
alarm with `targetType=vehicle`. A camera configured for push that has sent **zero** alarms is
broken on its side: pull its *Diagnose Information*; `Main Db is broken` means a corrupt config
database → **factory reset**, then redo 1–3 (the Vehicle target filter defaults OFF after a reset).
Point the Alarm Server at a dumb HTTP sink on the laptop if you need to see the verbatim body
([[lpr-camera]] §"auto-enter but not auto-exit").
**If the camera is a Dahua** (first unit inspected 2026-09-17, [[dahua-ipc-hfw2549t]]): factory
`192.168.1.108`, `admin` + a password set at first boot, web UI on port 80 (HTTPS off by default
on the bench unit). In the wizard: driver `dahua`, host, `admin` password, **channel 1 as printed** (the
driver sent `channel=0` → HTTP 400 until 2026-09-17; fixed). There is no HTTP Alarm Server to
point at the booth: events would be read by the server holding an `eventManager.cgi?action=attach`
stream (**not built yet** — a Dahua today gives snapshots + clock sync only, no lane busy/free
and no ANPR bridge), so no "assign first, then go back to the camera" step — but SMD must be set
to **Vehicle** on the camera. Set the time zone by hand; the app re-syncs the clock from the
booth like it does for Hikvision (the bench unit ran 1 h behind with DST off; NTP is useless on
the isolated VLAN). Five wrong logins lock `admin` for 5 minutes — check the password with one
`curl --digest` before assigning.
## 4. Radar (vehicle presence at the entry barrier)
A dry-contact sensor into a Dingtian input, nothing on the network. Check with the board's input
status (`00` query → `relays:inputs`) whether it **idles HIGH or LOW**; if it idles opposite the
button, set `activeLow` on that input in the wizard, or the gate inverts (tickets only when the
lane is empty). It is advisory: it gates the button, it never opens anything ([[hikvision-radar]],
[[entry-double-press]]).
## 5. Printers — three models, one byte stream, different status
All print the same ESC/POS bytes over **raw TCP 9100** or **USB (`/dev/usb/lpN`)**; what differs
is whether the app can see paper/cover state ([[printer-status-monitoring]],
[[printer-usb-transport]]). Roles: **entry-dispenser** outside at the lane, **booth-receipt**
inside (receipts, subscription cards, Z-reports, and the backup for entry tickets), **wash-desk**
if the site has a Car Wash ([[printer-roles-failover]]). Higher `failoverRank` = tried first.
| Model | Factory network | Config UI | App driver | Live status |
| --- | --- | --- | --- | --- |
| [[k200l-printer]] (Xprinter/ICS K200L, "POS-80" board; **the park-buzi unit**) | `192.168.123.100/24`, DHCP off | browser, port 80, no login: Configuration → fixed IP → Save → Restart | **`k200l`** | over LAN: cover / paper / cutter / off-line from `/prt_status.htm`; over USB: reachability only |
| [[rongta-printer]] (RP-series) | *not recorded — fill in* | status page `/prn_stat.htm` on port 80 | `rongta` | over LAN: full; USB: reachability |
| Cashino KP-300H | *not recorded — fill in* | *not recorded* | `escpos` (generic) | reachability only, by design — no trustworthy status source |
**Prefer LAN over USB** wherever a cable can reach: the booth sees a real amber "cover open, paper
out" while a roll is changed, and the `usblp` path (udev rule, node renumbering, the park-buzi
"offline after reload" mystery) drops out of the picture. USB needs the appliance's `usblp` +
udev rule ([[printer-usb-transport]] §Provisioning) and the printer shows up as `/dev/usb/lpN`,
numbered by plug order.
**Verify:** the wizard's "Test" only *probes* (opens the port / the device node) — it prints
nothing. Print something real: a subscription with a QR credential auto-prints its card and has a
**Reprint card** button; a payment prints a receipt; a wash till prints slips. Check the Cashino's
barcode with a real ticket (the KP-300H garbled overflowing barcodes until the geometry fix).
## 6. Order of work on site
1. Address plan on paper; VLAN ports patched; booth PC up with its device-VLAN address.
2. Dingtian: factory address → site address (browser) → wire button, radar, barriers.
3. Wizard: **controllers first** (the relay map + inputs); "Relay test" each barrier.
4. Readers: tool (IP, server, prefixes, format, symbologies) → wizard (serial, bind) → scan test.
5. Cameras: activate → IP → sub stream → wizard assign → Alarm Server + Vehicle target → drive-through
test → close the browser.
6. Printers: site address → wizard (role, rank) → print a card.
7. Walk-through: button + radar → ticket; QR entry then exit; RFID; a subscriber's plate at the
camera; pay at the booth → receipt → exit; paper reload on each printer while watching the
footer.
8. Record in the site record: every IP, serial, camera password, printer model, which relay is
which, photos of the labels. Remove the temporary laptop addresses. Log out of every device UI.
## Gaps to fill next time you hold the hardware
- Factory address and configuration tool of the **Cashino KP-300H** and the **Rongta RP** units
(both still unknown here).
- Where in `QRCode_v1_6_5.exe` the **symbologies** are selected (the Setting tab has no such field;
the IP / server / prefix fields are now described in §2).
- The **card technology** each site uses and which reader batch reads it, on the site record next to
the serial; and the result of the EM4100 test on the lab unit.
- Whether the camera activation was done with SADP or the browser at park-buzi, and the per-site
camera password location.
- Where the **site record** lives (a page per site under `wiki/entities/`? — park-buzi and park-2
have none yet; the Komodo stack env is the closest thing).
Related: [[appliance-provisioning]] · [[first-run-setup]] · [[device-registry]] ·
[[network-isolation]] · [[entry-exit-points]] · [[dingtian-relay]] · [[dingtian-dt008-reader]] ·
[[lpr-camera]] · [[hikvision-radar]] · [[k200l-printer]] · [[rongta-printer]] ·
[[printer-usb-transport]] · [[wsl-dev-networking]]