- zone-anpr-poc: H.264 instead of MJPEG (load, delay, a car in the zone, staff traffic, bad weather); the relay-less test copy is left running - event-driven-refactor (new): the user's decisions of 2026-11-23, what is not decided, what they touch in today's code; waits for the user's guidelines - passage-confirmation: the 2026-11-19 phase order superseded; where the video work lives - vision-hardening, zone-anpr-poc-review: on-screen label read as a plate (moved by the user), day-time oversized box, still pause carried over - pointers on vision-service, camera-live-view, lane-presence-and-anpr-entry, dingtian-vs-mqtt, entry gates, standing decisions, open questions, overview, index Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01RZgP5oZdzvo92Eouc9eRv5
2.8 KiB
type, tags, sources, updated, status
| type | tags | sources | updated | status | ||||
|---|---|---|---|---|---|---|---|---|
| decision |
|
2026-11-23 | settled |
Transport for the Relay Controller: HTTP/UDP now, MQTT parked
Decision (2026-06-15): use direct HTTP + UDP for the dingtian-relay controller now. MQTT is deliberately skipped, but kept on the radar for when the system scales.
Options the device supports
The Dingtian relay board speaks several protocols: Dingtian string (UDP/TCP), Dingtian binary
(UDP, optional multicast/password), HTTP CGI, HTTP input-link push (input_link_url),
Modbus (RTU/TCP/ASCII), and MQTT.
Why not MQTT (yet)
- A broker is new infrastructure on a deliberately single-purpose hardened appliance (disk-os-hardening) — another service to install, secure, supervise, and keep alive.
- Extra failure mode on the critical path. Today host→UDP→relay. MQTT inserts a broker on both control and event paths; if it stalls, the lane stalls — and there are 3 processes to debug, not 2.
- Doesn't fit offline-first for this scale. MQTT earns its keep with many devices/consumers and intermittent links. Here it's one host + a few devices on one isolated LAN, metres apart — request/response control + a single input event, no fleet.
- The device's MQTT input publish is periodic ("default every 30 s"), so it's not even a clean on-press event without relying on unverified on-change behaviour.
Why HTTP/UDP fits
- Relay control: direct UDP string protocol (port 60001) —
11=relay1 on,21=off,T1=toggle,11*=jog/pulse. No deps, no broker. - Input/button events: the device's
input_link_urlcan HTTP POST to the host backend when an input fires — real push, device calls our existing Fastify server directly, no broker. (Polling00status over UDP every ~50 ms is the self-contained fallback.) - Fewest moving parts; matches the local same-origin model already in use.
When to revisit MQTT
If the system grows to many lanes / many controllers, or multiple subsystems (LPR, payment, signage) all need to share events, a broker becomes a worthwhile central event bus. That aligns with the autonomous-direction roadmap at multi-lane scale — re-evaluate then. Until then, direct HTTP/UDP wins on simplicity and reliability.
The condition is met (2026-11-23)
The user decided a bus between the vision side, the server and the booth screen, as part of an event-driven refactor of the repository (event-driven-refactor). That is the case named above: several subsystems sharing events. Which bus is not decided, and nothing here says the relay controller moves onto it. The objections above (new infrastructure on the appliance, one more thing on the path that opens the barrier) still want an answer in that plan.